ESXi 6.7 + HP Array Utility
Show controller config
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config
Show controller status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show status
Show controller info
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show detail
Show controller info by slot
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 show detail
Controller re-scan
/opt/smartstorageadmin/ssacli/bin/ssacli rescan
Physical disks status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show status
Physical disk status full
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show detail
Logical disks status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld all show status
Logical disks status full
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 show
Create logical disk Raid0
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create logical disk Raid1
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
create logical disk Raid5
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete logical disk
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 delete
Add physical disk to array
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Add Spare disk
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Turn on Write Cache
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=enable
turn off Write Cache
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=disable
Delete physical disk
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd 2I:1:6 modify erase
Change cache proportions (cacheratio=readratio/writeratio)
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify cacheratio=100/0
Turn on cache without battery(No-Battery Write Cache option)
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify nbwc=enable
Turn off cache for logical disk
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
turn on cache for logical disk
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
Comments are currently closed.